BPJYL - 7547002, 5C CELL CONTROL

  • MSDS: BPJYL
  • Manufacturer: COULTER DIAGNOSTICS
  • Product Name: 7547002, 5C CELL CONTROL
  • National Stock Number: 6550-00N031803
Product Identification

Product ID:7547002, 5C CELL CONTROL
MSDS Date:03/12/1992
FSC:6550
NIIN:00N031803
MSDS Number: BPJYL

Responsible Party
COULTER DIAGNOSTICS
740 WEST 83RD ST
HIALEAH, FL 33014-0750
US

Emergency Phone: 800-424-8802

Info Phone: 305-822-8250

Cage: COLDI

Contractor
COULTER ELECTRONICS INC SALES DEPT
HIALEAH, FL 33010-2427 US

Telephone: 305-885-0131

Cage: 5M287

Ingredients

CHEMICAL SPILL KITS. CONTAIN ABSORBANT WASTE IN

RTECS: 9999999ZZ


TREATED HUMAN ERYTHROCYTES 6% ABNORMAL II


TREATED HUMAN ERYTHROCYTES 11% ABNORMAL I


TREATED HUMAN ERYTHROCYTES 39% NORMAL

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:NO Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:WARNING!!! POTNTL BIOHAZ MATL! EACH
DONOR UNIT USED IN PREPARATION OF THIS MATL WAS TESTED BY AN FDA
APPRVD METHOD FOR THE PRESENCE OF THE ANTIBODIES TO HUMAN
IMMUNODEFICIENCY VIRUS (HIV), HEPATITIS C VIRUS (HCV), AS WELL AS
FOR HEPATITIS B SURFACE ANTIGEN & FOUND TO BE NEG (WERE NOT RPTDLY
REACTIVE). (EFT OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:HLTH HAZ: BECAUSE NO TEST METH CAN OFFER
COMPLETE ASSURANCE THAT HUMAN IMMUNODEFICIENCY VIRUS
(HIV)/HEPATITIS B VIRUS/OTHER INFECTIOUS AGENTS ARE ABSENT, THIS
SPECIMEN/REAGENT SHLD BE HNDLD AT BIOSFTY LEVEL 2 AS RECOMMENDED
FOR ANY POTNTLYINFECTIOUS HUMAN SERUM/BLOOD SPECIMEN IN THE CTRS
FOR DISEASE CTL/ (SUPP DATA)
Medical Cond Aggravated by Exposure:NONE INDICATED.

First Aid

First Aid:SKIN: IMMEDIATELY WASH AFFECTED AREA(S) THOROUGHLY WITH SOAP
AND WATER. EYES: FLUSH WITH LARGE AMOUNTS OF WATER FOR A MINIMUM OF
15 MINUTES. INGEST: INDUCE VOMITING. SEEK IMMEDIATE MEDICAL
ATTENTION. INHAL: REMOVE TO FRESH AIR. SUPPORT BREATHING (GIVE
O2/ARTF RESP) .

Fire Fighting

Extinguishing Media:MEDIA SUITABLE FOR SURROUNDING FIRE .
Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED SCBA FULL PROTECTIVE
EQUIPMENT .
Unusual Fire/Explosion Hazard:NONE.

Accidental Release

Spill Release Procedures:NEUT SPILL BY TREATMENT W/STRONG SOLN OF
SODIUM HYPOCHLORITE (BLEACH). THE VOL OF BLEACH ADDED SHLD BE NOT
<10% OF SPILL VOL. ALLOW 10 MIN FOR COMPLETE NEUTRALIZATION. ABSORB
SPILL USING DISPOSABLE TO WELS OR ABSORBANT MATL FROM
COMMERCIAL,(ING 4)
Neutralizing Agent:SODIUM HYPOCHLORITE (BLEACH).

Handling

Handling and Storage Precautions:REFRIGERATED TEMP STOR (2-C). ABSORB
ANY SPRAY PRDCED WHILE REMOVING STOPPER BY COVERING STOPPER
W/ABSORBANT MATL (GAUZE OR PAPER WIPE).
Other Precautions:STORE PROD AT 2-8C; DO NOT FREEZE. MIX BY HAND ONLY.
DO NOT USE A MECH MIXER. WARM AT ROOM TEMP BEFORE EACH USE, RETURN
TO 2-8C WITHIN 30 MIN. CAUTION! HANDLE AS IF PROD WERE CAPABLE OF
TRANSMITTING D ISEASE.

Exposure Controls

Respiratory Protection:NONE REQUIRED. IF NEEDED, USE NIOSH/MSHA
APPROVED RESPIRATOR APPROPRIATE FOR EXPOSURE OF CONCERN .
Ventilation:NONE REQUIRED.
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:CHEMICAL WORKERS GOGGLES .
Other Protective Equipment:LAB COAT SHLD BE WORN DURING ROUTINE USE OR
SPILL CLEAN UP.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
EFTS OF OVEREXP: NATL INSTITUTES OF HLTH MANUAL - "BIOSAFETY IN
MICROBIOLOGICAL LABORATORIES", 1988. CAUTION! THIS PROD CNTNS
NON-STERILE HUMAN BLOOD/HUMAN BLOOD PRODS/HUMAN SERUM/HUMAN
URINE/HUMAN TI SS EXTRACTS, ETC. THE POTNTL FOR HUMAN DISEASE
TRANSMISSION EXISTS. HNDL AS BIOHAZ, CLASS II (CDC/NIH GUIDELINES).

Chemical Properties

HCC:K1
Spec Gravity:1.045
Appearance and Odor:DARK RED SUSPENSION.

Stability

Stability Indicator/Materials to Avoid:YES
Stability Condition to Avoid:NONE.
Hazardous Decomposition Products:NONE.

Disposal

Waste Disposal Methods:METHOD OF WASTE DISPOSAL MUST COMPLY WITH
FEDERAL, STATE AND LOCAL REQUIREMENTS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.